UltraSnap ATP Swab

UltraSnap ATP Swab

£3.00 ex. vat

UltraSnap™ is a user-friendly, all-in-one ATP sampling test used with Hygiena luminometers. This pen-sized sample collection device is easy to use, small, and environmentally friendly.

185 in stock

SKU: USP-SWB-OS Categories: , Tags: ,

UltraSnap

UltraSnap™ is a user-friendly, all-in-one ATP sampling test used with Hygiena luminometers. This pen-sized sample collection device is easy to use, small, and environmentally friendly.

In addition, UltraSnap uses a unique liquid-stable reagent providing superior accuracy, longer-lasting signal strength, and more reproducible results.

What is ATP testing?

Adenosine Triphosphate, or ATP, is the energy molecule found in all living things, making it a perfect indicator when trying to determine if a surface is clean or not.

Companies use ATP systems to rapidly verify surfaces have been cleaned thoroughly in food manufacturing and healthcare applications, and to ensure that biofilms are not developing on the surface that could affect quality.

Surface ATP test

With an ATP hygiene monitoring system, (or sometimes referred to as - an ATP sanitation monitoring system), ATP is brought into contact with Hygiena's unique liquid-stable reagent in the test device. Light is then emitted in direct proportion to the amount of ATP present in the sample, providing information on the level of contamination in seconds.

Liquid-stable chemistry

UltraSnap contains liquid-stable chemistry in the patented Snap-Valve™ bulb. This unique chemistry and design eliminate the need to reconstitute lyophilized pellets, enabling consistent and accurate results.

User guide

Completing a surface ATP test is a quick and easy three-step process that involves collection, activation, and mixing.

Step 1: Collection
Remove the swab from the tube and swab it on a 10cm x 10cm surface area in a criss-cross pattern. Make sure that you swap the surface evenly and apply sufficient pressure to get an accurate and reliable sample.

Step 2: Activation
Insert the swap back into the test tube. Turn on the luminometer and select the location to be tested (if you’ve selected this option).
Hold the test tube securely in your hand and use your thumb and forefinger to break the SnapValve by bending it. Next, squeeze the bulb twice to move the liquid into the tube, then shake for 5 seconds.

Step 3: Measurement
Insert the swab into the rear chamber of the luminometer and close the lid. Hold the device upright and press ‘okay’ to start the test. Results will be displayed in 15 seconds. You can discard your UltraSnap device in the recycling bin.